INTRODUCTION
In on-line UPS the inverter operates continuously because in online UPS battery power is supplied continuously to the load whether the main power is active or not. It provides constant voltage to equipment. In this UPS switching time (Transfer Time) from main power to battery power is zero because inverter continuously supplies power to the equipment irrespective of mains power.
Key Features
High performance and capability
IGBT based hi-frequency PWM inverter
Ideal for operation in all weather condition
Easy to install and simple in operation
Static bypass switch
Optimum backup and charging
Three phase to single phase transformer
Automatic voltage regulator
Special Features
Microcontroller based control circuits
Redundant design for high reliability
Float cum boost charger
Battery protection system
Paralleling possible up to n + 1
Wide input window
Precise computer grade power
Easy to install & operate
ADVANTAGES/BENEFITS
Soft start for inverter & charger
Very high efficiencies, very low energy loss
Less Noisy Operation
Fully Automatic
Pollution Free
Electronics Overload Protection
Easy to handle and use as indications and alarms are provided
Parallel Redundant UPS with SMPS
| Sr. No. | Parameter/Specifications | Specifications |
|---|---|---|
| 1 | Available Range | 1 KVA to 200 KVA Single & Three Phase |
| 2 | AC Input Voltage - Single Phase | 230V – 20% + 15% |
| AC Input Voltage - Three Phase | 415V – 20% + 15% | |
| Frequency | 50Hz ±10% | |
| 3 | UPS Capacity | DC Output Voltage |
| 50 KVA & above | 432V | |
| 10 KVA & above | 360V | |
| 5 KVA & above | 180V | |
| Below 5 KVA | 96V / 120V / 144V / 180V | |
| 4 | Technology | IGBT Double Conversion |
| Output Range | 230V AC for Single Phase 415V AC for Three Phase |
|
| Voltage Stability | ±1% for DC Input Variation & Output Load Variation | |
| Frequency | 50Hz ±0.05Hz (Crystal Controlled) or 60Hz ±0.06Hz or Any Optional Frequency | |
| Waveform | Sine Wave | |
| Harmonic Distortion | Less Than 3% | |
| Efficiency |
>93% for 360V DC & above >90% for 180V DC >85% for 48V DC/72V DC |
|
| Power Factor | 0.8 Lagging to Unity | |
| Crest Factor | >4:1 | |
| Transient Recovery | Within 3 Cycles | |
| Phase Displacement for 3Phase | 120° ±1° | |
| Audible Noise |
Less than 55dB at 1 Meter up to 10 KVA Less than 60dB at 1 Meter above 10 KVA |
|
| Dimensions (L x W x H) in mm | 501 x 400 x 825 | |
| 5 | Indications | Mains On, Load on Batteries, Battery Low, Inverter Overload, Load on Mains, Charger On, Inverter On |
| 6 | General Protections | EMI/RFI Filters, Snubber for all Semiconductors, Battery Over/Under voltage, Output Overload/Short Circuit, Output AC Over Voltage |
| 7 | Operating Temperature | 0°C – 50°C |
| Storage Temperature | 0°C – 60°C | |
| Relative Humidity | 95 RH | |
| Operating Altitude | Up to 2000 Meters | |
| 8 | Metering (Optional) | Analog/Digital meter for Input/Output Voltage, Battery Current, Output Frequency |
APPLICATIONS OF THE ONLINE UPS
Computer Labs
CNC Machines
Medical Equipments
Laboratory Instruments
1 Phase In 1 Phase Out ( 1 KVA to 10 KVA )
3 Phase In 1 Phase Out ( 10 KVA to 25 KVA )
3 Phase In 3 Phase Out ( 5 KVA to 50 KVA )
3 Phase In 1 Phase Out ( 10 KVA to 25 KVA )